Skip to content

Research & aeroacoustics

Arrays built around your experiments

Anechoic chambers, wind tunnels, reverberant rooms: arrays of 32 to 1,024 channels, open all the way down to the raw signal.

2 m cubic array in an anechoic chamber

What holds research back today

01

Costly, fixed systems

With condenser microphones, one channel costs around €1,000, and the array geometry is set once and for all.

02

Black boxes

Without the raw signals, you cannot apply your own processing or compare methods.

03

One-off set-ups

Arrays that surround the source, sit flush in a wall, or span metres to reach low frequencies: every experiment has its own geometry.

You choose the geometry

Beams of eight microphones that fit together like a construction kit: a line, a plane or a volume, from 8 to 1,024 synchronous channels.

  1. A line

    Up to about twenty metres across, to locate low frequencies.

  2. A plane

    Flush with a wind-tunnel wall or facing an object, for near-field holography.

  3. A volume

    Sphere or cube: an array that surrounds the source and locates in every direction.

What Mµ brings

Fully open

Raw signals, an open binary format and a Python SDK: your post-processing stays yours.

A construction kit

You define the array geometry, one beam of eight microphones at a time.

Up to 1,024 synchronous channels

To instrument large objects or whole volumes in a single acquisition.

Analogue inputs and triggering

Synchronous analogue channels for your other sensors, plus an external trigger.

A lab-sized budget

About 10× cheaper per channel than a condenser-microphone system.

Use cases

Aeroacoustic imaging in open-jet wind tunnels

Wall-pressure measurement

Source localization in reverberant rooms

Near-field holography and modal analysis

Voice directivity studies

AI research on sound

Projects

Arrays designed with and for research laboratories.

Wind-tunnel test section lined with microphone arrays on its walls

2018 · ANR project MAMIES

3D imaging in an anechoic wind tunnel

Context
The BETI anechoic wind tunnel at the Pprime institute (University of Poitiers).
Need
Locate in three dimensions the aeroacoustic sources of an open-jet flow.
Mµ solution
A 1,024-microphone array deployed around the jet.
Result
3D images of the aeroacoustic sources.
Geodesic 1,024-microphone array, about 2 m across, in an anechoic chamber

2024

How the voice radiates

Context
A study carried out in an anechoic chamber with a CNRS acoustics laboratory.
Need
Measure the sound radiated by the voice in every direction.
Mµ solution
A spherical array of 1,024 MEMS microphones.
Cubic array in a reverberant room

PhD thesis · MODO project

Identifying sources in a reverberant room

Context
PhD thesis of H. Demontis.
Need
Identify sound sources where reflections blur localization.
Mµ solution
A reverberant room instrumented with 1,024 microphones.
Compact spherical 256-microphone array

2022 · ANR project Haikus

Deep learning for augmented acoustics

Context
A project with Sorbonne University, IRCAM and INRIA.
Mµ solution
A compact sphere of 256 microphones.

Several research centres, in France and abroad, are equipped with Mµ systems.

Typical setup

Mµ256

256-channel synchronous concentrator

Custom array

Planar or spherical, shaped to your experiment

MµBoard

Acquisition, beamforming and Python SDK

See the range

See also

Equip your laboratory

Describe your experiment: we will suggest a setup and send you a quote.